VCC General Work Permit

Street View of 416 Chartres St
Replace roofs at Green and Brown rated structures per attached materials stamped VCC approved 05/23/2024. Flat roofs to receive new medium gray Durolast roof system. Pitched roofs to receive natural slate, as follows.
• Remove existing Fire Free Plus roofing material
• Repair and/or replace underlayment as necessary
• Install new 12" x 18" natural slate (grey/green), using copper nails
• Install/repair half round copper gutters and flashing
• Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing.

Note: Trash chutes are required for removal of debris from all roofs
 All work must conform to standard VCC policies & guidelines
 Permit does not allow for cap flashing on parapets, chimneys or surrounding walls
Torch-applied roofing is not permitted in the Vieux Carré.

NOTE: Copper cap flashing approved as indicated in drawings for framed walls with brick veneer. Solid masonry walls to receive mortar cap per detail provided by roofer.
Ref code CRSQBT
?