942 N Rampart St

VCC General Work Permit

Street View of 942 N Rampart St
Install three (3) new gooseneck light fixtures as indicated, per attached materials stamped VCC approved 10/27/2023.
Remove all existing, unpermitted and/or unshielded light fixtures
Fixtures must be centered over the window/door openings
Fixtures shall be prefinished in "Evergreen"
All wiring shall be placed in conduits
All conduits shall be placed along the inside corners of building surfaces as much as possible, such as along gallery/balcony purlins at the deck line, and painted to match the adjacent surfaces.
All fixtures shall use lamps with the following criteria: 3000K color temperature, 80+ color rendering index, and 800-1200 lumens per bulb
Ref code Y5MV0Z
?