816 Saint Ann St

VCC General Work Permit

Street View of 816 Saint Ann St
to replace 8 sythetic slate shingles scattered throughout the roof. replacmetn will be to match existing.
wire brush the existing flashing cemet a the base of the 2 front chimneys.
apply fresh mortar if needed to the chimney bases, VCC MORTAR ONLY (see formula bellow.
**THIS PERMIT DOES NOT ALLOW FOR THE USE OF LASTISEAL SEALANT
Mortar: No more than:
• 1 part Portland Cement, to
• 3 parts lime,
• 9 parts sand, and
• enough water to form a workable mix.

PREPACKAGED MIXES ARE NOT PERMITTED.

The resulting mortar should range in color from white to beige but should not be grey in color. When repointing, all mortar to be tooled to match existing joint profiles. Consult with VCC staff if existing joint profile indeterminate.

Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows:
• no greater than 1:12 part Portland Cement, to
• 3 parts lime, and
• 9 parts sand,
• 6 lbs./cubic yard hair or fiber, and
• enough water to form a workable mix.

Finish coat is 1/4" in total thickness proportioned as follows:
• No more than 1 Part Portland cement,
• 3 Parts Lime,
• 9 Parts Sand,
• Enough water to form a workable mix.

PREPACKAGED MIXES ARE NOT PERMITTED
Ref code 6FG32E