• Remove broken and damaged roof slates as needed.
• Repair and/or replace underlayment as necessary
• Install new 12" x 18" natural slate, using copper nails. Replacement slate must match existing slate to be retained.
• Install/repair half round copper gutters and flashing
• Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing.
• Metal cap-flashing on the parapets or chimneys is not allowed. Remove existing metal cap and install mortar cap with embedded metal mesh, per typical details, attached.
PARAPET NOTE: Existing metal parapet cap on Decatur side parapet of 516 Wilkinson, shared with 510-12 Wilkinson, is not to be altered or replaced without coordination with the property owner(s) at 510-12 Wilkinson. Submit joint proposal, consent letter, and scope of work to VCC staff before any work at this parapet.
DORMER NOTE: Do not perform any work at dormers that alters the appearance of the dormer in any way, other than roof repair/replacement. Millwork repair/replacement at dormers is not included in this permit. Do not alter flashing or obscure any millwork features.

Note: Trash chutes are required for removal of debris from all roofs
 All work must conform to standard VCC policies & guidelines
 Permit does not allow for cap flashing on parapets, chimneys or surrounding walls
Torch-applied roofing is not permitted in the Vieux Carré.

All repair/replacement work shall match existing in col