Mortar: No more than:
• 1 part Portland Cement, to
• 3 parts lime,
• 9 parts sand, and
• enough water to form a workable mix.

PREPACKAGED MIXES ARE NOT PERMITTED.

The resulting mortar should range in color from white to beige but should not be grey in color. When repointing, all mortar to be tooled to match existing joint profiles. Consult with VCC staff if existing joint profile indeterminate.

Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows:
• no greater than 1:12 part Portland Cement, to
• 3 parts lime, and
• 9 parts sand,
• 6 lbs./cubic yard hair or fiber, and
• enough water to form a workable mix.

Finish coat is 1/4" in total thickness proportioned as follows:
• No more than 1 Part Portland cement,
• 3 Parts Lime,
• 9 Parts Sand,
• Enough water to form a workable mix.

PREPACKAGED MIXES ARE NOT PERMITTED.

LATH OF ANY KIND IS NOT ALLOWED.