Remove existing roofing material
Repair and/or replace underlayment as necessary
Install new 12_” x 18” natural slate (grey/green), using copper nails
Install/repair new galvanized flashing
Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing.
Metal cap-flashing on the parapets or chimneys is not allowed
Install new ceme3nt on chimney bases. VCC mortar is to be used. only 6-8" inches.
Mortar: No more than:
1 part Portland Cement, to
3 parts lime,
9 parts sand, and
enough water to form a workable mix.

PREPACKAGED MIXES ARE NOT PERMITTED.


Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré.
Ref code 4JUR41
?