Remove existing roofing material
Repair and/or replace underlayment as necessary
Install new 12” x 18” natural slate (grey/green), using copper nails
Install/repair half round copper gutters and flashing
Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace any broken tiles as needed, to match existing.
Metal cap-flashing on the parapets or chimneys is not allowed
replace any roof jacks an plumbing stack penetrations to match in size location and material
install shop fabricated tapered roof vents with wind bands to match exisitng in size, shape and location.

Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré.