Junk happens. Text a photo to Mel and make it disappear. → 500 Chartres St – NOLA.Today

500 Chartres St

VCC General Work Permit

Street View of 500 Chartres St
To restucco the first floor of the cabinet gallery and the first floor of the adjacent wings using natural hydraulic lime stucco.
Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows:
• no greater than 1:12 part Portland Cement, to
• 3 parts lime, and
• 9 parts sand,
• 6 lbs./cubic yard hair or fiber, and
• enough water to form a workable mix.
Finish coat is 1/4" in total thickness proportioned as follows:
• No more than 1 Part Portland cement,
• 3 Parts Lime,
• 9 Parts Sand,
• Enough water to form a workable mix.
PREPACKAGED MIXES ARE NOT PERMITTED.
LATH OF ANY KIND IS NOT ALLOWED.
The resulting mix should range in color from off-white to beige but should not be grey in color.
Note: RATIO OF PORTLAND CEMENT NOT TO EXCEED 1:12.
An incorrect mortar can damage an historic building and it materials.
Ref code 6PZFMS
?