727 Saint Ann St

VCC General Work Permit

Street View of 727 Saint Ann St
Remove existing roofing material
Repair and/or replace underlayment as necessary
install new ice and water shield
Install new 12” x 18” natural slate (grey/green), using copper nails
Install new copper flashing and drip edge
install new lead jacks in same location
Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing.
Metal cap-flashing on parapets or chimneys is not allowed
Rubber mastic and liquid applied waterproofing/sealants are not allowed on parapet walls or parapet caps unless explicitly permitted
NEW MORTAR CAP ON PARAPET WALL. NO METAL CAP FLASHING ALLOWED.

Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré.
Ref code 4ATYGB
?