Opt out of physical junk mail → 620 Dauphine St – NOLA.Today

620 Dauphine St

VCC General Work Permit

Street View of 620 Dauphine St
FORTIFIED ROOF
Remove existing roofing material on main roof and dormers
Repair and/or replace underlayment as necessary
remove and replace roof decking as needed
Install new 18” x 10” CUPA natural slate (black), using copper nails
Install new copper flashing around dormers and chimney
Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing.
Metal cap-flashing on the parapets or chimneys is not allowed
NO NEW GUTTERS OR DOWNSPOUTS ARE PERMITTED

Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré.
Ref code VM2UQU
?