434 Chartres St

VCC General Work Permit

Street View of 434 Chartres St
MAIN ROOF:
Remove existing roofing material
Repair and/or replace underlayment as necessary
Install new 16” x 10” natural slate (grey/black), using copper nails
Install/repair half round copper gutters and flashing
Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing.
Metal cap-flashing on the parapets or chimneys is not allowed
If synthetic tiles are used, they are NOT to be wrapped/ capped at the edge of the roof or dormers
REAR ROOF:
TPO gray/ non reflective
any stucco applied/ used is to be VCC approved stucco mix. See below:
Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows:
• no greater than 1:12 part Portland Cement, to
• 3 parts lime, and
• 9 parts sand,
• 6 lbs./cubic yard hair or fiber, and
• enough water to form a workable mix.
Finish coat is 1/4" in total thickness proportioned as follows:
• No more than 1 Part Portland cement,
• 3 Parts Lime,
• 9 Parts Sand,
• Enough water to form a workable mix.

PREPACKAGED MIXES ARE NOT PERMITTED.
Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré.
Ref code 76P0TZ