1027 Royal St

VCC General Work Permit

Street View of 1027 Royal St
ALL WORK TO MATCH EXISITNG
ALL WORK ON MAIN BUILING FRONT FACADE GALLERY ROOF ONLY
remove and replace existing slate on gallery roof. replacement slate to be Cupa 16"x10" (gray green)
remove and replace underlayment and decking
remove and replace ridge tiles on gallery roof, replacment tiles to be Hecker (light brown)
remove and replace flashing where necessary, all replacemtn work to match exisitng
ridge tiles to be installed using VCC approved stucco and mortar mix, see below:
Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows:
• no greater than 1:12 part Portland Cement, to
• 3 parts lime, and
• 9 parts sand,
• 6 lbs./cubic yard hair or fiber, and
• enough water to form a workable mix.
PREPACKAGED MIXES ARE NOT PERMITTED.
Ref code 1KHAXE
?