Opt out of physical junk mail → 829 Saint Peter St – NOLA.Today

829 Saint Peter St

Renovation (Non-Structural) Permit

Street View of 829 Saint Peter St
ALL WORK ON BOURBON ELEVATION ONLLY
Remove existing incorrectly applied thinset mortar and lathe, remove loose underlying stucco and apply VCC approved stucco.
Paint to match
Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows:
• no greater than 1:12 part Portland Cement, to
• 3 parts lime, and
• 9 parts sand,
• 6 lbs./cubic yard hair or fiber, and
• enough water to form a workable mix.
Finish coat is 1/4" in total thickness proportioned as follows:
• No more than 1 Part Portland cement,
• 3 Parts Lime,
• 9 Parts Sand,
• Enough water to form a workable mix.
PREPACKAGED MIXES ARE NOT PERMITTED.
LATH OF ANY KIND IS NOT ALLOWED.
NOTE: Permit issued in response to violations. Work shall commence no less than 30 days after permit is issued. Work must be completed no less than 60 days after work begins. Owner will call VCC for final inspection upon completion of work.
Ref code E04GPR
?