Unsubscribe from postal mail → 2901 Constance St – NOLA.Today

2901 Constance St

HDLC Certificate of Appropriateness

Street View of 2901 Constance St
installation of 26kw generac generator with 100 Amp transfer switch, remove existing breaker panel ( bevausr of space. And install transfer switch with main breaker and 20 circuit breaker panel in one.
-re wire service and connect transfer switch to meter
-install 28’ conduit and generator cable and secure to lower portion of wall behind garden. Attach to stand for support from house exterior
- terminate and test
- install 2 ground rods, # 4 ground cable, bonding bridge for current code. nstall 28’ of 1.25” galv. Gas line from meter to generator. Will be supported next to conduit on exterior of house then supported on stand
- pressure test at 4 psi
- return to do startup and activation after inspections
Ref code 1BK6UB
?