ALL WORK ON MAIN HOUSE ONLY
NO NEW GUTTERS OR DOWNSPOUTS
NO NEW VENTS OF ANY KIND
NO PARAPET CAP FLASHING OF ANY KIND
Remove existing roofing material
Repair and/or replace underlayment as necessary
Install new 18” x 12” natural slate (unfading gray), using copper nails
Install/repair half round copper flashing
insatll new drip edge, copper
insall new valley, v-channel, copper
install new step flashing, copper
detach and reinstall Heker V ridge ridge tiles. Replace broken tiles as needed, to match existing.
Metal cap-flashing on the parapets or chimneys is not allowed


Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré.

All repair/replacement work shall match existing in color, size, material, detail, profile and exposure.