Unsubscribe from postal mail → 830 Bourbon St – NOLA.Today

830 Bourbon St

VCC General Work Permit

Street View of 830 Bourbon St
NOTE: Permit issued in response to violations. Work shall commence no less than 30 days after permit is issued. Work must be completed no less than 60 days after work begins. Owner will call VCC for final inspection upon completion of work.
Permit to address VCC Violations 24-01267-vccnop per applicaiton and materials recieved 12/2/24 and stamped VCC approved 12/3/24.
To repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached)
Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure.
All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached).

VOIDS IN THE BRICK ARE NOT TO BE FILLED WITH MORTAR. BROKEN, DETERIORATED BRICKS MUST BE REPLACED WITH BRICKS MATCHING THE PREVIOUS.

All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. The resulting mix should range in color from off-white to beige but should not be grey or white in color.

MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES.

Doing so will result in a STOP WORK ORDER being placed on the property and violation case will be opened on the property.

Lath or adherents of any kind are prohibited unless preapproved by VCC staff prior to install
Ref code ZXGXXT
?