Unsubscribe from postal mail → 610 N Rampart St – NOLA.Today

610 N Rampart St

VCC General Work Permit

Street View of 610 N Rampart St
Main roof only. TPO roof to remain
Remove existing roofing material
Repair and/or replace underlayment as necessary
Install new inspire sythetic slate (grey)
remove and replace all step falshing
Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing.
Metal cap-flashing on the parapets or chimneys is not allowed
If synthetic tiles are used, they are NOT to be wrapped/ capped at the edge of the roof or dormers

Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines
Permit does not allow for cap flashing on parapets, chimneys or surrounding walls.Torch-applied roofing is not permitted in the Vieux Carré.

Ref code 2DMP48