Junk happens. Text a photo to Mel and make it disappear. → 1040 Chartres St – NOLA.Today

1040 Chartres St

VCC General Work Permit

Street View of 1040 Chartres St
Repoint misc areas of gable wall and parapet. ALL NEW JOINTS ARE TO MATCH EXISTING IN SIZE AND COLOR.
to visually inspect and ousnd the mortar joints on teh entire west wall of buildign C
repoint where necessary using VCC mortar mix MIXED ON SITE
To repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached)
Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure.
All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached).
All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. The resulting mix should range in color from off-white to beige but should not be grey or white in color.

MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES.

Doing so will result in a STOP WORK ORDER being placed on the property and violation case will be opened on the property.
Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work.
Ref code 2BRND0
?