232 Bourbon St

VCC General Work Permit

Street View of 232 Bourbon St
ALL WORK IS TO MATCH EXISTING
Sand and paint, replace wood members as needed on balcony’s, decking and stairs on rear and front elevations (only real wood is allowed in the VCC. sythetic materials are not allowed.
Remove deteriorated floor boards, stringers, and fascia boards.
Install new 3"x4" beaded stringers, 5/4x4 wood T&G floorboards, and 7/8" fascia with ½" bead, all as per VCC Standard Detail Sheet No. 12 (attached).
repair stucco as needed throughout property using VCC stucco mix, see below:
Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows:
• no greater than 1:12 part Portland Cement, to
• 3 parts lime, and
• 9 parts sand,
• 6 lbs./cubic yard hair or fiber, and
• enough water to form a workable mix.

Finish coat is 1/4" in total thickness proportioned as follows:
• No more than 1 Part Portland cement,
• 3 Parts Lime,
• 9 Parts Sand,
• Enough water to form a workable mix.

PREPACKAGED MIXES ARE NOT PERMITTED.
LATH OF ANY KIND IS NOT ALLOWED.
Ref code EEVCLM
?